Model No. 9335
PAG L95 Li-Ion Power Circle Battery.
PAGlok connector.
Model No. 9335V
PAG L95 Li-Ion Power Circle Battery.
V-Mount compatible connector.
Model No. 9335A
PAG L95 Li-Ion Power Circle Battery.
Snap-on compatible connector.
Construction:
The casing for these models consists of high-impact polycarbonate injection mouldings, featuring an internal cradle designed to protect the cells from impact damage. The cells have welded interconnections of low-resistance nickel strap. The batteries are sealed and non user-serviceable.
Cells:
Premium grade Lithium-Ion sealed rechargeable cylindrical cells.
Voltage:
14.8V nominal. The battery contains 12 cells connected in series/parallel. Each cell has a nominal voltage of 3.7V.
Capacity:
Nominal 6.5 ampere-hours, with a charge voltage of 4.2V per cell, and discharged at
the one-hour rate.
Charge Time:
The battery may require up to 3 hours to charge from the fully discharged state.
Charge time will be less if the battery is partially charged at the start.
Output Current:
Rated maximum continuous output current is 5.5 amperes.
Protection:
The battery incorporates the following safety shutdown systems:
3 over-current shutdown systems.
2 over-voltage shutdown systems.
2 under-voltage shutdown systems.
2 thermal shutdown systems (including a non-resetting thermal fuse).
All protection circuits within the battery are designed to withstand the leakage of electrolyte.
PAG Power Circle Display.
The PAG Power Circle is a micro-driven coulometric capacity indicator that displays charge status in terms of percentage. If the battery is 100% charged, then all 4 segments of the Power Circle will be lit.
The battery is self-diagnostic. Prior to any cumulative effect developing as permanent damage, the battery will report that it requires a service by pulsing the LED's simultaneously (when the display button is pressed) with a 50% on/off duty cycle. A complete charge followed by a full discharge will clear the condition, and the battery will confirm this by again showing the normal display when the button is pressed.
If the button is held in continuously, the display will operate for a short period and will then automatically turn off. This ensures that the display button cannot be held-in permanantly during transit or storage.
Operating Temperature Range:
Optimum discharge efficiency is achieved within the temperature range +10°C to +40°C.
|