Model No. 9792
PAG
AR124PLD
Four sequential charging channels.
Four PAGlok connectors and four PP90 (2.1mm) connectors.
Discharge-then-charge program. |
|
Model No. 9793
PAG
AR124NPD
Four sequential charging channels.
Four NP1 pockets and four PP90 (2.1mm) connectors.
Discharge-then-charge program. |
|
Model No. 9795
PAG
Pulsar
Four sequential charging channels.
Four Snap-on compatible and four PP90 (2.1mm) connectors.
Discharge-then-charge program.
Battery interrogation feature. |
| |
2. Range of Batteries Charged:
Nickel-Cadmium batteries having nominal voltages of between 4.8V and 14.8V, and nominal capacities of between 1Ah and 10Ah.
Nickel-Metal Hydride batteries of reputable manufacture having nominal voltages of between 4.8V and 14.8V, and nominal capacities of between 1Ah and 10Ah.
PAG Lithium-Ion batteries
(PAG V-Mount Li-Ion batteries require Charge Adaptor Model No. 9617).
(Sony V-Mount Lithium-Ion batteries require PAG Intelligent Charge Adaptor Model No. 9610).
3. Battery Connections:
PAGlok: Patented, professional PAG locking connector compatible with all PAGlok batteries. Incorporates self-cleaning military-type beryllium-copper leaf contacts.
NP1: Polarised connector suitable for Ni-Cd and Ni-MH NP1-type batteries. Incorporates superior blade-type beryllium-copper contacts.
PP90 (2.1mm): Polarised connector suitable for 2.1mm coaxial DC power connectors.
NOTE: centre pin negative.
Snap-on compatible: Patented professional connector compatible with PAG Li-Ion batteries (Models 9366, 9383 and 9335A), and Anton-Bauer batteries (not Dionic).
Battery Interrogation (Pulsar Model 9795 only):
PAG Pulsar Model 9795 incorporates a battery interrogation facility, allowing the charger to display the following data which is recorded by the battery:
Serial number.
Date of manufacture.
Ah loaded.
Operating capacity.
Percentage state of charge.
Chemistry.
Battery temperature.
4. Main Charge Program:
Auto Mode: automatically selects the correct charge current.
Manual selection: 2A, 3A or 4A charge current.
Li-Ion voltage-charge program: only available with PAG intelligent batteries or suitable PAG intelligent adaptor. PAG intelligent batteries automatically over-ride the Auto Mode or Manual selection, and control their own charge regime.
5. Discharge-then-Charge Program:
This program discharges the battery, automatically determining the fully-discharged condition, and then fully charges it. The discharge capacity and the subsequent charge loaded into the battery can be displayed on the screen.
6. Recovery Charge:
This special program conditions the battery for a period of one hour. The charger will then auto-matically enter the Main Charge program, which will run until the battery is fully charged. This program also recovers PAG Li-Ion batteries which have been over-discharged to the point where the internal safety protection circuit has tripped.
7. Ancillary Charging Programs:
The following programs may be automatically entered after charging:
Balancing Charge.
Self-adjusting Maintenance Charge (not applied to PAG Li-Ion batteries).
8. Self Test Program:
The internal microcomputer constantly monitors the battery under charge or process as well as the operation of the chargers own functions which will be shut down to a safe condition should any of the tests fail.
9. Mains Input:
90-139V or 140-270V ~ autoselected.
Frequency 47-63 Hz.
Maximum power consumption 120W.
10. Output Protection:
Charger protected against short circuit, open circuit, excess battery voltage and reverse battery voltage.
11. AC Mains Failure Protection:
Should mains failure occur during a charging program, or whilst the charger is connected, it will shut down to a safe condition.
12. User Interface:
The LCD screen has a display area of 94mm x 18mm, which displays 2 lines of text, with 24 characters per line. The screen incorporates electro-luminescent backlighting with on/off control via the front panel soft function switch. This switch also provides for the selection of programs and interrogation of charge and discharge data.
13. Safety:
Designed to comply with electrical safety standard BS EN 60065.
NOTE: U.K. plugs are fitted with a 1" fuse to BS1362 rated 5A as standard.
14. European Union Directives:
Complies with the following EU Directives:
EMC Directive 89/336/EU.
Low Voltage Directive 73/23/EU.
15. Operating Temperature Range:
0ºC to 40ºC (+32ºF to +104ºF).
16. Overall Dimensions:
9792 AR124PLD:
81.5mm high x 168mm wide x 240mm deep.
(3.2", 3.5" with feet extended, x 6.6" x 9.5" approx.).
9793 AR124NPD:
78mm high x 142mm wide x 240mm deep.
(3.1" x 5.6" x 9.5" approx.).
9795 Pulsar:
81.5mm x 168mm x 240mm approx.
(3.2" high x 6.6" wide x 9.5" deep).
17. Weight:
9792 AR124PLD:
1.23kg (2.70lbs approx.).
9793 AR124NPD:
1.07kg (2.35lbs approx.).
9795 Pulsar:
1.23kg (2.70lbs approx.).
18. Typical Battery Charging Times:
| Capacity |
Time 2A |
Time 3A |
Time 4A |
| 1Ah |
30mins |
20mins |
15mins |
| 2Ah |
60mins |
45mins |
30mins |
| 4Ah |
120mins |
90mins |
60mins |
| 5Ah |
150mins |
105mins |
75mins |
| 7Ah |
|
150mins |
105mins |
10Ah
|
|
|
150mins |
These times are approximate only, and assume the battery is fully discharged. Charging times will be less if the battery is already partially charged.
NOTE: PAG intelligent batteries communicate with the charger, and automatically optimise the charging output (independently of the manual selection) to enhance performance and safety. The above charging times do not apply to these batteries. |